AI562
Subscribe to get prices
Model: AI562
Order No: 3ABD10094789
SKU: 10000080660001
Size: 135.00 mm,34.00 mm,74.00 mm
Weight: 0.12kg
Brief Introduction
AI562
The ABB AI562 is an analog input module of the AC500-eCo series for RTD temperature measurementSupply voltage: 24V DC, permissible voltage range - 15% to + 20%.Power Consumption: The current drawn from a 24V DC supply is approximately 5mA, with an inrush current of 0.05A²s at start-up and a maximum ripple of 5%.Reverse Voltage Protection: Yes.Maximum power consumption in the module: 1.1W.Mounting position: horizontal or vertical, operating temperature range from 0°C to +60°C when installed horizontally, reduced output load to 50% per bank when installed vertically, and operating temperature range from 0°C to +40°C.Cooling method: natural convection cooling, which cannot be obstructed by cable ducts or other components in the control cabinet.Number and type of input channels: 2 configurable RTD channels.Channel grouping: 1 group of 2 channels each.Resolution: RTD of 0.1°C/0.1°F, resistance of 15 bits + sign bits.Input Type: Modular Ground Reference RTD for 2-Wire and 3-Wire RTD Temperature Detectors.Input range: support PT100, PT1000, NI100, NI1000, 150Ω, 300Ω, etc.Module update time: less than 1s for all channels.Channel input resistance: >100kΩ.Input filter attenuation: -3dB at 3.6kHz.Analog Value Conversion Error: Typical values depend on the RTD and are up to ±0.6% of full scale at 25°C and up to ±2% of full scale at 0°C to 60°C or electromagnetic interference.A/D conversion time: 140ms typical per channel.Unused Input: Openable and should be configured as Unused.Input data length: 4 bytes.Sensor internal power consumption: 1mW max.Interference suppression: can be carried out upon request.Maximum input voltage: 30V DC at the detection end and 5V DC at the source side.Basic error (resistance): 0.1% of full scale.Repeatability: 0.05% of full scale.Overvoltage Protection: Yes, up to 30V DC.Wire loop resistance: 800hPa/
Description
Supply voltage: 24V DC, permissible voltage range - 15% to + 20%.
Power Consumption: The current drawn from a 24V DC supply is approximately 5mA, with an inrush current of 0.05A²s at start-up and a maximum ripple of 5%.
Reverse Voltage Protection: Yes.
Maximum power consumption in the module: 1.1W.
Mounting position: horizontal or vertical, operating temperature range from 0°C to +60°C when installed horizontally, reduced output load to 50% per bank when installed vertically, and operating temperature range from 0°C to +40°C.
Cooling method: natural convection cooling, which cannot be obstructed by cable ducts or other components in the control cabinet.
Number and type of input channels: 2 configurable RTD channels.
Channel grouping: 1 group of 2 channels each.
Resolution: RTD of 0.1°C/0.1°F, resistance of 15 bits + sign bits.
Input Type: Modular Ground Reference RTD for 2-Wire and 3-Wire RTD Temperature Detectors.
Input range: support PT100, PT1000, NI100, NI1000, 150Ω, 300Ω, etc.
Module update time: less than 1s for all channels.
Channel input resistance: >100kΩ.
Input filter attenuation: -3dB at 3.6kHz.
Analog Value Conversion Error: Typical values depend on the RTD and are up to ±0.6% of full scale at 25°C and up to ±2% of full scale at 0°C to 60°C or electromagnetic interference.
A/D conversion time: 140ms typical per channel.
Unused Input: Openable and should be configured as Unused.
Input data length: 4 bytes.
Sensor internal power consumption: 1mW max.
Interference suppression: can be carried out upon request.
Maximum input voltage: 30V DC at the detection end and 5V DC at the source side.
Basic error (resistance): 0.1% of full scale.
Repeatability: 0.05% of full scale.
Overvoltage Protection: Yes, up to 30V DC.
Wire loop resistance: <20Ω. Maximum cable length: 10m for unshielded wires and 100m for shielded wires. Galvanic isolation: The input group is galvanically isolated from the rest of the module to prevent interference from the internal power supply and other modules. Degree of protection: IP20 housing. Operating humidity: 95% max, non-condensing. Working air pressure: >800hPa/<2000m.