SIMATIC DP, ELECTRONIC MODULES FOR ET200PRO 4 AI RTD HIGH FEATURE, PT100; PT200; PT500; PT1000; NI100; NI200; NI500; NI1000; CHANNEL DIANOSTICS; INCLUSIVE BUS MODULE, CONNECTING MODULE IO 6ES7194-4..00-0AA0 MUST BE ORDERED SEPERATELY |
|
Supply voltage |
Load voltage L+ |
Rated value (DC) |
24 V |
Reverse polarity protection |
Yes; against destruction |
Input current |
from backplane bus 3.3 V DC, max. |
10 mA; Typical |
Power losses |
Power loss, typ. |
0.7 W |
Address area |
Address space per module |
Address space per module, max. |
8 byte |
Analog inputs |
Number of analog inputs |
4 |
Cycle time (all channels) max. |
83 ms; 83 ms at 50 Hz; 69 ms at 60 Hz |
Technical unit for temperature measurement adjustable |
Yes |
Input ranges |
Voltage |
No |
Current |
No |
Thermocouple |
No |
Resistance thermometer |
Yes |
Resistance |
Yes |
Input ranges (rated values), resistance thermometers |
Cu 10 |
No |
Ni 100 |
Yes |
Input resistance (Ni 100) |
10000 kΩ |
Ni 1000 |
Yes |
Input resistance (Ni 1000) |
10000 kΩ |
Ni 120 |
Yes |
Input resistance (Ni 120) |
10000 kΩ |
Ni 200 |
Yes |
Input resistance (Ni 200) |
10000 kΩ |
Ni 500 |
Yes |
Input resistance (Ni 500) |
10000 kΩ |
Pt 100 |
Yes |
Input resistance (Pt 100) |
10000 kΩ |
Pt 1000 |
Yes |
Input resistance (Pt 1000) |
10000 kΩ |
Pt 200 |
Yes |
Input resistance (Pt 200) |
10000 kΩ |
Pt 500 |
Yes |
Input resistance (Pt 500) |
10000 kΩ |
Input ranges (rated values), resistors |
0 to 150 ohms |
Yes |
Input resistance (0 to 150 ohms) |
10000 kΩ |
0 to 300 ohms |
Yes |
Input resistance (0 to 300 ohms) |
10000 kΩ |
0 to 600 ohms |
Yes |
Input resistance (0 to 600 ohms) |
10000 kΩ |
0 to 3000 ohms |
Yes |
Input resistance (0 to 3000 ohms) |
10000 kΩ |
Resistance thermometer (RTD) |
Characteristic linearization |
for resistance thermometer |
Ptxxx, Nixxx |
Characteristic linearization |
Parameterizable |
Yes |
Cable length |
Cable length, shielded, max. |
30 m |
Analog value creation |
Measurement principle |
integrating |
Integrations and conversion time/resolution per channel |
Resolution with overrange (bit including sign), max. |
15 bit |
Integration time, ms |
20 / 16,667 |
Interference voltage suppression for interference frequency f1 in Hz |
50 / 60 Hz |
Conversion time (per channel) |
20.625 ms; 20.625 ms at 50 Hz; 17.25 ms at 60 Hz |
Smoothing of measured values |
Parameterizable |
Yes |
Step: None |
Yes; 1 x cycle time |
Step: low |
Yes; 4 x cycle time |
Step: Medium |
Yes; 16 x cycle time |
Step: High |
Yes; 64 x cycle time |
Encoder |
Connection of signal encoders |
for resistance measurement with two-wire connection |
Yes; Line resistances are also measured |
for resistance measurement with three-wire connection |
Yes |
for resistance measurement with four-wire connection |
Yes |
Errors/accuracies |
Linearity error (relative to input range), (+/-) |
0.05 % |
Temperature error (relative to input range), (+/-) |
0.0020 %/K |
Crosstalk between the inputs, min. |
-50 dB |
Repeat accuracy in steady state at 25 °C (relative to input area), (+/-) |
0.015 % |
Operational limit in overall temperature range |
Resistance thermometer, relative to input area, (+/-) |
0.175 % |
Basic error limit (operational limit at 25 °C) |
Resistance thermometer, relative to input area, (+/-) |
0.125 % |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency |
Series mode interference (peak value of interference < rated value of input range), min. |
50 dB |
common mode voltage (USS < 2.5 V) , min. |
70 dB; Interference voltage < 5 V |
Interrupts/diagnostics/status information |
Diagnostic messages |
Wire break |
Yes |
Group error |
Yes |
Overflow/underflow |
Yes |
Diagnostics indication LED |
Group error SF (red) |
Yes |
Parameter |
Diagnosis: wire break |
Yes |
Load voltage |
No |
Measurement type/range |
R4L / R3L / R2L/ TR4L / TR3L / TR2L |
Interference frequency suppression |
50 / 60 Hz |
Group diagnostics |
Yes |
Overflow/underflow |
Yes |
Unit |
Degrees C / Degrees F |
Galvanic isolation |
Galvanic isolation analog inputs |
between the channels |
No |
between the channels and the backplane bus |
Yes |
Permissible potential difference |
between the inputs (UCM) |
5 Vpp AC |
between MANA and M internally (UISO) |
500 V DC |
Isolation |
Isolation checked with |
500 V DC |
Dimensions |
Width |
45 mm |
Height |
130 mm |
Depth |
35 mm |
Weights |
Weight, approx. |
150 g |
Status |
Jun 16, 2014 |