Model | FS-N15CN | |||
Type | IP66 Fiberoptic Amplifier, 1 output type | |||
Output | NPN | |||
I/O format | M8 connector *1 | |||
Main unit/expansion unit | Main unit | |||
Control output | 1 output | |||
External input | 1 | |||
Output toggle | Light-ON/Dark-ON switchable | |||
Light source LED | Red 4-element LED (wavelength 630 nm) | |||
Timer function | Timer OFF/OFF delay/ON delay/One-shot | |||
Response time | 50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) | |||
Number of interference prevention units | 0 units (expansion not possible) | |||
Case size | H30.3mm 1.19" x W9.8mm 0.39" x L71.8mm 2.38" | |||
Unit expansion | 0 units (expansion not possible) | |||
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |||
Rating | Power voltage | 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less | ||
Current Consumption | Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2 | |||
Environmental resistance | Enclosure rating | IP66*3*4 | ||
Ambient light | Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less | |||
Ambient temperature | -20 to +55 °C -4 to 131 °F (No freezing) | |||
Relative humidity | 35 to 85 % RH (No condensation) | |||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions | |||
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |||
Material | Adapter | Glass-reinforced PBT | ||
Weight | Approx. 30 g | |||
*1 Use a cable of 30 m 98.43' or less. |
- USD
- CNY
- HKD
- EUR
- العربية
- čeština
- dansk
- Deutsch
- Ελληνικά
- English
- Español
- Français
- ic
- Italiano
- Netherlands
- norsk Språk
- język polski
- pt
- Português
- 中文


FS-N15CP
Subscribe to get prices
Model: FS-N15CP
Order No: FS-N15CP
SKU: 10000020299801
Size: 100.00 mm,120.00 mm,25.00 mm
Weight: 0.03kg
Brief Introduction
FS-N15CP
ModelFS-N15CNTypeIP66 Fiberoptic Amplifier, 1 output typeOutputNPNI/O formatM8 connector *1Main unit/expansion unitMain unitControl output1 outputNPN open collector 24 V or less; maximum 100 mA or less, residual voltage 1 V or lessExternal input1Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)Output toggleLight-ON/Dark-ON switchableLight source LEDRed 4-element LED (wavelength 630 nm)Timer functionTimer OFF/OFF delay/ON delay/One-shotResponse time50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Number of interference prevention units0 units (expansion not possible)Case sizeH30.3mm 1.19" x W9.8mm 0.39" x L71.8mm 2.38"Unit expansion0 units (expansion not possible)Protection circuitReverse polarity protection, Over-current protection, Surge absorberRatingPower voltage12 to 24 VDC ±10 %, Ripple (P-P) 10 % or lessCurrent ConsumptionNormal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*2Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)Environmental resistanceEnclosure ratingIP66*3*4Ambient lightIncandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or lessAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsMaterialAdapterGlass-reinforced PBTWeightApprox. 30 g*1 Use a cable of 30 m 98.43' or less.*2 Increases 100 mW (4.0 mA) for High Speed mode*3 About the enclosure rating when a small-diameter fiber unit (the diameter of the cable is ø1.3 or ø1.0) is used. IP66/IP65 cannot be satisfied when the type whose diameter is ø1.3 and terminal can be separated (FU-4F/ 66/91/93/43/63/63T etc.) is used. When any small-diameter fiber units except for the above are used, IP65 is applied.*4 In any of the following cases, the enclosure rating IP66/IP65 cannot be satisfied.When the Fiber Unit and KEYENCE's M8 connector cable are not connected (Recommended conditions to tighten up the M8 connector: Tighten it by hand first.Then retighten it as much as 1/16-1/8 of a rotation with pliers.)When the Fiber Unit and KEYENCE's M8 connector cable are not connectedWhen the dust cover of the Sensor Amplifier is openWhen there is debris in the dust coverWhen the waterproof adapter A/B are not used at the time of installation of a small-diameter fiber unit.
Description