Model | LR-X250C | |||
Type | M8 Connector Type*1 | |||
Detecting Distance | 30 to 250 mm 1.18" to 9.84" | |||
Standard Detectable Deviation | 30 to 180 mm: 9 mm 1.18" to 7.09": 0.35" | |||
Display Resolution | 1 to 2 mm 0.04" to 0.08" | |||
Spot Size | Approx. 0.8 mm × 1.2 mm 0.03" × 0.05" | |||
Response Time | 500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable | |||
Light Source | Type | Green laser (505 nm) | ||
Laser Class | Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3) | |||
IO-Link | Specification v1.1/COM2 (38.4 kbps) | |||
Functions | Timer Function | Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot | ||
I/O | Control Output | NPN open collector/PNP open collector, N.O./N.C selectable. *4 | ||
External Input | External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4 | |||
Protection Circuit | Protection against reverse power connection, protection against output overcurrent, | |||
Power supply | Power voltage | 16 to 30 VDC (including 10% ripple (P-P) or less), class 2 | ||
Power consumption | During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current) | |||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | ||
Ambient light | Incandescent lamp: 8000 lux or less | |||
Ambient temperature | -10°C to +50°C 14°F to + 122°F (no freezing) | |||
Relative humidity | 35 to 85% RH (no condensation) | |||
Vibration resistance | 10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes | |||
Shock resistance | 1000 m/s2 (100G) 6 times each for X, Y, and Z axes | |||
Material | Head Case: SUS316L; Head Lens Cover: PSU | |||
Accessories | Instruction manual, laser warning label | |||
Weight | Approx. 35 g | |||
*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link. |
- USD
- CNY
- HKD
- EUR
- العربية
- čeština
- dansk
- Deutsch
- Ελληνικά
- English
- Español
- Français
- ic
- Italiano
- Netherlands
- norsk Språk
- język polski
- pt
- Português
- 中文


LR-X250C
Subscribe to get prices
Model: LR-X250C
Order No: LR-X250C
SKU: 10000024992701
Size: 12.00 cm,10.00 cm,3.50 cm
Weight: 0.03kg
Brief Introduction
LR-X250C
ModelLR-X250CTypeM8 Connector Type*1Detecting Distance30 to 250 mm 1.18" to 9.84"Standard Detectable Deviation30 to 180 mm: 9 mm 1.18" to 7.09": 0.35"180 to 250 mm: 18 mm 7.09" to 9.84": 0.71"Display Resolution1 to 2 mm 0.04" to 0.08"Spot SizeApprox. 0.8 mm × 1.2 mm 0.03" × 0.05"(at a detecting distance of 250 mm 9.84")Response Time500 µs*2/1 ms/3 ms/10 ms/200 ms SelectableLight SourceTypeGreen laser (505 nm)Laser ClassClass 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3)IO-LinkSpecification v1.1/COM2 (38.4 kbps)FunctionsTimer FunctionTimer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shotI/OControl OutputNPN open collector/PNP open collector, N.O./N.C selectable. *430 VDC or lower, 50 mA or lower, Residual voltage 2 V or lowerExternal InputExternal Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lowerInput time 3 ms or more ON, 20 ms or more OFF(25 ms or more ON, 25 ms or more OFF when External Set is selected only)Protection CircuitProtection against reverse power connection, protection against output overcurrent,protection against output surge, protection against reverse output connectionPower supplyPower voltage16 to 30 VDC (including 10% ripple (P-P) or less), class 2Power consumptionDuring normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)Environmental resistanceEnclosure ratingIP65/IP67 (IEC60529)Ambient lightIncandescent lamp: 8000 lux or lessSunlight: 8000 lux or lessAmbient temperature-10°C to +50°C 14°F to + 122°F (no freezing)Relative humidity35 to 85% RH (no condensation)Vibration resistance10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axesShock resistance1000 m/s2 (100G) 6 times each for X, Y, and Z axesMaterialHead Case: SUS316L; Head Lens Cover: PSUHead Gasket: FKM (lens cover), EVM (cable)Cable: PVCAmplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POMAmplifier M8 Connector: SUS303AccessoriesInstruction manual, laser warning labelWeight Approx. 35 g*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link.*2 If 500 µs is selected, the following limitations apply.· Only 2-point calibration can be performed.· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.*3 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice No. 56.*4 The I/O can be selected from the following combinations. Control output × 2, Control output + External input
Description