Model | PS-N10 | |||
Type | Zero line | |||
Output | - | |||
Main unit/Expansion unit | Expansion unit | |||
I/O | Control outputs | None*1 | ||
External input | None | |||
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |||
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max. | |||
Control output | ― | |||
Number of interference prevention units | 4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled) | |||
Response time | 500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) | |||
External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |||
Case size | H 32.6 mm 1.28"× W 9.8 mm 0.39" × L 78.7 mm 3.1" | |||
Unit expansion | Up to 16 units (Up to 17 units including 1 main unit can be connected in total.) | |||
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |||
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS | ||
Power consumption | Normal: 810 mW or less (at 30V. 28 mA max. at 24 V, 34 mA max. at 12 V) | |||
Environmental resistance | Ambient temperature | -20 to +55 °C -4 to 131 °F (No freezing)*3 | ||
Relative humidity | 35 to 85 % RH (No condensation) | |||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions | |||
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |||
Material | Case | Main unit and cover material: Polycarbonate | ||
Cable | PVC | |||
Weight | Approx. 20 g | |||
*1 Counted as one output when added to a NU Series communication unit. |
- USD
- CNY
- HKD
- EUR
- العربية
- čeština
- dansk
- Deutsch
- Ελληνικά
- English
- Español
- Français
- ic
- Italiano
- Netherlands
- norsk Språk
- język polski
- pt
- Português
- 中文


PS-N10
Subscribe to get prices
Model: PS-N10
Order No: PS-N10
SKU: 10000069070901
Size: 12.00 cm,10.00 cm,3.50 cm
Weight: 0.02kg
Brief Introduction
PS-N10
ModelPS-N10TypeZero lineOutput-Main unit/Expansion unitExpansion unitI/OControl outputsNone*1External inputNoneOutput selectionLIGHT-ON/DARK-ON (switch-selectable)Timer functionTimer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max.Control output―Number of interference prevention units4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled)Response time500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)External inputInput time 2 ms (ON)/20 ms (OFF) or more*2Case sizeH 32.6 mm 1.28"× W 9.8 mm 0.39" × L 78.7 mm 3.1"Unit expansionUp to 16 units (Up to 17 units including 1 main unit can be connected in total.)Protection circuitReverse polarity protection, Over-current protection, Surge absorberRatingPower voltage24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPSPower consumptionNormal: 810 mW or less (at 30V. 28 mA max. at 24 V, 34 mA max. at 12 V)Eco on mode: 700 mW or less (at 30V. 24 mA max. at 24 V, 27 mA max. at 12 V) Eco Full mode: 490 mW or less (at 30V. 17 mA max. at 24 V, 20 mA max. at 12 V)Environmental resistanceAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)*3Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsMaterialCaseMain unit and cover material: PolycarbonateCablePVCWeightApprox. 20 g*1 Counted as one output when added to a NU Series communication unit.*2 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected.*3 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F.
Description