PS-N12P

Subscribe to get prices

Model: PS-N12P

Order No: PS-N12P

SKU: 10000069071401

Size: 12.00 cm,10.00 cm,3.50 cm

Weight: 0.06kg

In Stock

Brief Introduction

PS-N12P

ModelPS-N12PTypeCableOutputPNPMain unit/Expansion unitExpansion unitI/OControl outputs1 outputExternal inputNoneOutput selectionLIGHT-ON/DARK-ON (switch-selectable)Timer functionTimer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max.Control outputPNP open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max,residual voltage 1.2 V max. (when the output current is 10 mA or less)/2.2 V max. (when the output current is 10 to 100 mA)Number of interference prevention units4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled)Response time500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)External inputInput time 2 ms (ON)/20 ms (OFF) or more*1Case sizeH 32.6 mm 1.28"× W 9.8 mm 0.39" × L 78.7 mm 3.1"Unit expansionUp to 16 units (Up to 17 units including 1 main unit can be connected in total.)Protection circuitReverse polarity protection, Over-current protection, Surge absorberRatingPower voltage24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPSPower consumptionNormal: 860 mW or less (at 30V. 30 mA max. at 24 V, 35 mA max. at 12 V)Eco on mode (ALL): 750 mW or less (at 30V. 26 mA max. at 24 V, 28 mA max. at 12 V) Eco Full mode: 540 mW or less (at 30V. 19 mA max. at 24 V, 21 mA max. at 12 V)Environmental resistanceAmbient temperature-20 to +55 °C -4 to 131 °F (No freezing)*2Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance500 m/s2, 3 times in each of the X, Y, and Z directionsMaterialCaseMain unit and cover material: PolycarbonateCablePVCWeightApprox. 65 g*1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected.*2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F.

Description

Model

PS-N12P

Type

Cable

Output

PNP

Main unit/Expansion unit

Expansion unit

I/O

Control outputs

1 output

External input

None

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Timer function

Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9999 ms, Maximum error against the setting value: ±10% max.

Control output

PNP open collector 30 V, (without expansion) 100 mA max., (with expansion) 20 mA max,
residual voltage 1.2 V max. (when the output current is 10 mA or less)/2.2 V max. (when the output current is 10 to 100 mA)

Number of interference prevention units

4 for TURBO/SUPER/ULTRA/MEGA (When set to DOUBLE, the number of interference-prevention units will be doubled)

Response time

500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)

External input

Input time 2 ms (ON)/20 ms (OFF) or more*1

Case size

H 32.6 mm 1.28"× W 9.8 mm 0.39" × L 78.7 mm 3.1"

Unit expansion

Up to 16 units (Up to 17 units including 1 main unit can be connected in total.)

Protection circuit

Reverse polarity protection, Over-current protection, Surge absorber

Rating

Power voltage

24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS

Power consumption

Normal: 860 mW or less (at 30V. 30 mA max. at 24 V, 35 mA max. at 12 V)
Eco on mode (ALL): 750 mW or less (at 30V. 26 mA max. at 24 V, 28 mA max. at 12 V) Eco Full mode: 540 mW or less (at 30V. 19 mA max. at 24 V, 21 mA max. at 12 V)

Environmental resistance

Ambient temperature

-20 to +55 °C -4 to 131 °F (No freezing)*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Case

Main unit and cover material: Polycarbonate

Cable

PVC

Weight

Approx. 65 g

*1 Input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected.
*2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit.
One or two more units connected: -20 to +55 °C -4 to 131 °F; 3 to 10 more units connected: -20 to +50 °C -4 to 122 °F; 11 to 16 more units connected: -20 to +45 °C -4 to 113 °F.

Unsubscribe