Model | PX-10P | |||
Type | Cable type | |||
Output | PNP | |||
Response time | 500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) | |||
Output selection | LIGHT-ON/DARK-ON | |||
Indicator lamp | - Operation indicator:Red LED x 2, DSC orange LED x 1 | |||
Detection mode | Light intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor] | |||
Shift function | Variable between –1999 and 9999 | |||
Timer function | Timer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shot | |||
Control output | PNP open-collector 30 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max. | |||
External input | Input time 2 ms (ON)/20 ms (OFF) min. | |||
Interference prevention | Up to 4 units (in all power modes)*1 | |||
Rating | Power voltage | 12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*2 | ||
Power consumption | Standard mode:50 mA max. at 24 V/55 mA max. at 12 V | |||
Environmental resistance | Enclosure rating | IEC: IP67/JEM: IP67/NEMA: 4X | ||
Ambient temperature | -10 to +55 °C 14 to 131 °F (No freezing)*3 | |||
Relative humidity | 35 to 85 % RH (No condensation) | |||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions | |||
Case material | Housing:PBT, display:PSU, display cover/connector cover:SUS304, radiator plate:SUS304, gasket:NBR | |||
Weight | Approx. 100 g (Including cable) | |||
*1 The received light intensity may vary somewhat when the sensor head's cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affected |
- USD
- CNY
- HKD
- EUR
- العربية
- čeština
- dansk
- Deutsch
- Ελληνικά
- English
- Español
- Français
- ic
- Italiano
- Netherlands
- norsk Språk
- język polski
- pt
- Português
- 中文


PX-10P
Subscribe to get prices
Model: PX-10P
Order No: PX-10P
SKU: 10000018400101
Size: 12.00 cm,10.00 cm,3.50 cm
Weight: 0.10kg
Brief Introduction
PX-10P
ModelPX-10PTypeCable typeOutputPNPResponse time500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)Output selectionLIGHT-ON/DARK-ONIndicator lamp- Operation indicator:Red LED x 2, DSC orange LED x 1- Dual digital monitor:Dual 7-segment display[Preset value (4-digit green LED) and current value (4-digit red LED) illuminated together,current value range:0 to 65504, excess gain:0 P to 999 P]- Hold function:Possible to display both peak and bottom hold values. Selectable from 5 variations.- Bar LED monitor [Excess gain displayed (85% to 115% in 7 steps)]- Scaling displayDetection modeLight intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor]Shift functionVariable between –1999 and 9999Timer functionTimer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shotTimer duration selectable:1 ms to 9999 msMaximum error against the setting value:10% max.Control outputPNP open-collector 30 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max.External inputInput time 2 ms (ON)/20 ms (OFF) min.Interference preventionUp to 4 units (in all power modes)*1RatingPower voltage12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*2Power consumptionStandard mode:50 mA max. at 24 V/55 mA max. at 12 VPower saving mode:40 mA max. at 24 V/45 mA max. at 12 VEnvironmental resistanceEnclosure ratingIEC: IP67/JEM: IP67/NEMA: 4XAmbient temperature-10 to +55 °C 14 to 131 °F (No freezing)*3Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsCase materialHousing:PBT, display:PSU, display cover/connector cover:SUS304, radiator plate:SUS304, gasket:NBRWeightApprox. 100 g (Including cable)*1 The received light intensity may vary somewhat when the sensor head's cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affectedsomewhat when using multiple units installed adjacent to each other. Fine-tune the sensitivity (increase the setting) for adjacent layouts.*2 Use a 24 VDC power voltage when using a head light transmitting cable of 3 m 9.8' or more (PX-H71/H71TZ) or 10 m 32.8' or more (PX-H72).*3 When using multiple units connected adjacently, the ambient temperature varies with the conditions below.2 to 4 Units: -10 to +50 °C 14 to 122 °F, 5 to 17 Units: -10 to +45 °C 14 to 133 °F.
Description