Model | MU-N12 | |||
Main unit/Expansion unit | Expansion unit | |||
Response time | Depends on the connected sensor model*1 | |||
Expansion units | Up to 4 expansion units*2 | |||
I/O | Control output | 4 max., | ||
External input | 5 max., | |||
Analog output | - | |||
Protection circuit | Protection against reverse power connection, | |||
Power supply | Power voltage | 24 VDC, ripple (P-P) 10% or less, Class 2 or LPS | ||
Current consumption | 55 mA or less (without load)*5 | |||
Sensor | Allowable sensor current | 150 mA or less | ||
N-bus | Allowable passing | 900 mA or less | ||
Environmental resistance | Ambient temperature | -20 to +50 °C -4 to 122 °F (No freezing) | ||
Relative humidity | 35 to 85 % RH (No condensation) | |||
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions | |||
Shock resistance | 1,000 m/s2, 6 times in each of the X, Y, and Z directions | |||
Material | Case and dust cover: Polycarbonate | |||
Weight | Approx. 70 g | |||
*1 The response time, as well as the types and number of inputs and outputs that are available, vary depending on the connected sensor model. |
- USD
- CNY
- HKD
- EUR
- العربية
- čeština
- dansk
- Deutsch
- Ελληνικά
- English
- Español
- Français
- ic
- Italiano
- Netherlands
- norsk Språk
- język polski
- pt
- Português
- 中文


MU-N12
Subscribe to get prices
Model: MU-N12
Order No: MU-N12
SKU: 10000063277501
Size: 12.00 cm,10.00 cm,3.50 cm
Weight: 0.07kg
Brief Introduction
MU-N12
ModelMU-N12Main unit/Expansion unitExpansion unitResponse timeDepends on the connected sensor model*1Expansion unitsUp to 4 expansion units*2I/OControl output4 max.,NPN open collector/PNP open collector selectable,24 V or less,Main unit: 50 mA or less*3,Expansion unit: 20 mA or less,Residual voltage: 2 V or less,N.O./N.C. selectable*1*4External input5 max.,Short-circuit current: NPN: 1 mA or less,PNP: 2 mA or less,For the applied voltage, see wiring diagrams(page 3 of the instruction manual)*1*4Analog output-Protection circuitProtection against reverse power connection,power supply surge, output overcurrent,output surge, and reverse output connectionPower supplyPower voltage24 VDC, ripple (P-P) 10% or less, Class 2 or LPSCurrent consumption55 mA or less (without load)*5SensorconnectionspecificationAllowable sensor current150 mA or lessN-busconnectionspecificationAllowable passingcurrent900 mA or lessEnvironmental resistanceAmbient temperature-20 to +50 °C -4 to 122 °F (No freezing)Relative humidity35 to 85 % RH (No condensation)Vibration resistance10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directionsShock resistance1,000 m/s2, 6 times in each of the X, Y, and Z directionsMaterialCase and dust cover: PolycarbonateButtons: PolyacetalDisplay panel: PMMAWeightApprox. 70 g*1 The response time, as well as the types and number of inputs and outputs that are available, vary depending on the connected sensor model.For details, see the specific "MU-N Series User's Manual" for the model that will be connected.*2 Up to 5 N-bus devices, including the main unit (or network unit), can be linked together.*3 20 mA or less: When using the expansion unit.*4 For more information on Control output, External input, and Analog output wire allocation, please refer to the table of "Power Cable Pin Layout" on page 3 of this manual.*5 1185 mA or less when a sensor is attached, 4 outputs (with loads) are used, and expansion units are connected.
Description