Laser Sensor LS-H901

LS-H901

Subscribe to get prices

Model: LS-H901

Order No:

SKU: 10000056563901

Size: 16.00 cm,5.00 cm,7.00 cm

Weight: 100.00g

In Stock

Brief Introduction

LS-H901

Regulatory compliance EMC Directive, RoHS Directive<br/> Applicable amplifiers LS-501(P), LS-501(P)-C2<br/> (Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. <br/> This is because there is a possibility of sensing becoming unstable.)<br/> Sensing range:H-SP mode 1m 3.281 ft<br/> (Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)<br/> (Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector.<br/> In addition, the sensing range is the possible setting range for the reflector. <br/> The sensor can detect an object less than 0.01 m 0.033 ft away.<br/> Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received.<br/> In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. <br/> The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)

Description

As of November 23, 2023
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number LS-H901
Part Number LS-H901
Regulatory compliance EMC Directive, RoHS Directive
Applicable amplifiers LS-501(P), LS-501(P)-C2
(Note:When using the thru-beam type LS-H101□ or LS-H102□, do not set the receiving light sensitivity (gctL) of the applicable LS-500 series amplifier to level 2 or less. This is because there is a possibility of sensing becoming unstable.)
Sensing range:H-SP mode 0.01 to 1m 0.033 to 3.281 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:FAST mode 0.01 to 1m 0.033 to 3.281 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:STD mode 0.01 to 1m 0.033 to 3.281 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:U-LG mode 0.01 to 1.5m 0.033 to 4.921 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:U-LG 0.01 to 2m 0.033 to 6.562 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Sensing range:HYPR 0.01 to 2.5m 0.033 to 8.202 ft
(Note:The sensing range of the coaxial reflective type sensor is specified for white non-glossy paper (100 × 100 mm 3.937 × 3.937 in) as the object.)
(Note:The sensing ranges for coaxial retroreflective type sensors are values for the RF-330 reflector. In addition, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.01 m 0.033 ft away. Note that if there are white papers or specular objects near the sensor head, reflected light from these objects may be received. In such cases, use the amplifier unit’s receiving sensitivity function to lower the sensitivity, change the response time, or move the sensor head away from the target object. The incident light intensity may vary with the condition of the reflector surface. When using one of the applicable LS-500 series amplifiers, leave an adequate safety margin when setting the threshold.)
Spot size Approx. dia. 6 mm dia. 0.236 in or less (at a distance from the sensor head of 1 m 3.281 ft)
Sensing object Opaque, translucent, or transparent object
(Note:Make sure to confirm detection with an actual sensor before use.)
Operation indicator Orange LED (lights up when the amplifier output is ON)
Protection IP40 (IEC)
Ambient temperature -10 to +55degrees + 14 to + 131 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -20 to +70degrees -4 to +158 degrees Fahrenheit
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 100 m / s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Emitting element:Type Red semiconductor laser diode
Emitting element:Peak emission wavelength 660 nm 0.026 mil
Emitting element:Laser class Class 1 [IEC / JIS / FDA]
(Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and )Radiological Health) under the FDA (Food and Drug Administration).
Emitting element:Max. output 1mW
Material Enclosure: PBT
Indicator cover: Polycarbonate
Beam-emitting / receiving surfaces: Glass
Cable 0.15 mm2 2-core two parallel shielded cables, 2 m 6.562 ft long
(Note:Cable cannot be extended.)
Weight Net weight: 50 g approx.
Gross weight: 85 g approx.
Accessory MS-LS-1(Mounting bracket): 1pc.
RF-330(Refrector): 1pc.