Artikelnummer 6GK1160-4AT00
Product type designation CP 1604 TS
COMMUNICATIONS PROCESSOR CP1604 TS PC/104 PLUS CARD (32 BIT; 33/66MHZ; 3.3/5V) WITH ASIC ERTEC 400 FOR CONNECT. TO PROFINET IO WITH 4-PORT-REAL-TIME-SWITCH PATH CONSTANT VERSION
Transmission rate
Transfer rate
● at the 1st interface 10 ... 100 Mbit/s
Interfaces
Number of electrical connections
● at the 1st interface / acc. to Industrial Ethernet 4
● for power supply 1
Design of the electrical connection
● at the 1st interface / acc. to Industrial Ethernet RJ45 port via connection board
Supply voltage, current consumption, power loss
Type of voltage / of the supply voltage DC
Type of voltage supply / optional external supply Yes
Supply voltage
● 1 / from backplane bus 5 V
● external 24 V
Relative symmetrical tolerance / for DC
● at 5 V 5 %
● at 24 V 20 %
Consumed current
● 1 / from backplane bus / for DC / maximum 0.8 A
● from external supply voltage / for DC / at 24 V / maximum 0.3 A
Active power loss 4 W
Active power loss / in switch mode / maximum 4.1 W
Design, dimensions and weight
Module format PCI-104
Width 90 mm
Height 24 mm
Depth 95 mm
Mounting type Screw mounting
Number of plug-in cards of same design / plug-in / per PC station 1
Number of units / Note -
Performance data
Performance data / PROFINET communication / as PN IO-Controller
Software / for PROFINET IO communication / required No
Number of PN IO devices / on PROFINET IO controller / usable / total 128
Number of PN IO IRT devices / on PROFINET IO controller / usable 64
Amount of data
● as user data for input variables / as PROFINET IO controller / maximum 8192 byte
● as user data for input variables / as PROFINET IO controller / maximum 8192 byte
● as user data for input variables per PN IO device / as PROFINET IO controller / maximum 1433 byte
● as user data for output variables per PN IO device / as PROFINET IO controller / maximum 1433 byte
Performance data / PROFINET communication / as PN IO-Device
Amount of data
● as user data for input variables / as PROFINET IO device / maximum 1433 byte
● as user data for input variables / as PROFINET IO device / maximum 1433 byte
● as user data for input variables / for each sub-module as PROFINET IO device 254 byte
● as user data for input variables / for each sub-module as PROFINET IO device 254 byte
● as user data for the consistency area for each sub-module 254 byte
Number of submodules / per PROFINET IO-Device 64
Product functions / management, configuration
Product function / MIB support Yes
Protocol / is supported
● SNMP v1 Yes
● DCP Yes
● LLDP Yes
Product functions / Diagnosis
Product function
● Web-based diagnostics Yes
● Port diagnostics Yes
Product functions / switch
Product feature / Switch Yes
Product function / switch-managed No
Product function / with IRT / PROFINET IO switch Yes
Product functions / Redundancy
Software / for redundancy function / required No
Product function
● Ring redundancy Yes
● Redundancy manager Yes
● Media Redundancy Protocol (MRP) Yes
Standards, specifications, approvals
Standard
● for safety / from CSA and UL CAN/CSA C22.2 & UL 60950-1
● for emitted interference EN 61000-6-3
● for interference immunity EN 61000-6-3
Certificate of suitability
● CE marking Yes
● C-Tick Yes