PSE250-600-70-1
Subscribe to get prices
Model: PSE250-600-70-1
Order No: 1SFA897113R7000
SKU: 10000038551801
Size: 190.00 mm,550.00 mm,236.50 mm
Weight: 13.90KG
Brief Introduction
PSE250-600-70-1
Technical parametersRated Operating Voltage:208 ... 600 V ACRated control supply voltage (U.)s):100 ... 250 V ACRated control circuit voltage (Uc):DC Operation 24 VRated Frequency (f):50/60 HzMain Circuit 50 / 60 HzRated Operating Power - Coaxial Connection (PE):(230 V) 75 kW(400 V) 132 kW(500 V) 160 kWRated Operating Current - Coaxial Connection (IE):250 APercentage of Safety Factor:100 %Overload Protection:Build-in electronic overload protectionIntegrated Electronic Overload:YesStarting capacity at maximum rated current Ie:4xIe for 10sSlope Time:0 ... 30 second [unit of time]1 ... 30 second [unit of time]Initial voltage at start-up:30 ... 70 %Special Buck Ramps:No %Current Limiting Function:1.5 ... 7xIeInner triangle connection switch:notRunning Signal Relay:beBypass Signal Relay:YesFault Signal Relays:YesOverload Signal Relay:beAnalog Output:4… 20 mAComplete Start Ramp Signal Indication (LED):GreenReady to start/standby signal indication ON (LED):GreenOperational signal indication R (LED):GreenAcceleration/Deceleration Signal Indication (LED):GreenProtection Signal Indication (LED):YellowFault Signal Indication (LED):RedFor 50% of the time off, 50% of the time on, under 3.5*Ie current, the number of starts per hour:10Communication:FiledBusPlug(Optional)Ingress Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00Terminal Type:Main Circuit: BarsMain circuit connection capacity:Hole Diameter 10.2 mmWidth and Thickness 20x5 mmControl circuit connection capacity:Rigid 1 x 2.5 mm²Rigid 2 x 1.5 mm²Power supply circuit connection capacity:Rigid 1 x 2.5 mm²Tightening torque:Control Circuit 0.5 N·mMain Circuit 28 N·mSupply Circuit 0.5 N·mProduct range:PSE250
Description
Rated Operating Voltage:
208 ... 600 V AC
Rated control supply voltage (U.)s):
100 ... 250 V AC
Rated control circuit voltage (Uc):
DC Operation 24 V
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operating Power - Coaxial Connection (PE):
(230 V) 75 kW
(400 V) 132 kW
(500 V) 160 kW
Rated Operating Current - Coaxial Connection (IE):
250 A
Percentage of Safety Factor:
100 %
Overload Protection:
Build-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting capacity at maximum rated current Ie:
4xIe for 10s
Slope Time:
0 ... 30 second [unit of time]
1 ... 30 second [unit of time]
Initial voltage at start-up:
30 ... 70 %
Special Buck Ramps:
No %
Current Limiting Function:
1.5 ... 7xIe
Inner triangle connection switch:
not
Running Signal Relay:
be
Bypass Signal Relay:
Yes
Fault Signal Relays:
Yes
Overload Signal Relay:
be
Analog Output:
4… 20 mA
Complete Start Ramp Signal Indication (LED):
Green
Ready to start/standby signal indication ON (LED):
Green
Operational signal indication R (LED):
Green
Acceleration/Deceleration Signal Indication (LED):
Green
Protection Signal Indication (LED):
Yellow
Fault Signal Indication (LED):
Red
For 50% of the time off, 50% of the time on, under 3.5*Ie current, the number of starts per hour:
10
Communication:
FiledBusPlug(Optional)
Ingress Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Main circuit connection capacity:
Hole Diameter 10.2 mm
Width and Thickness 20x5 mm
Control circuit connection capacity:
Rigid 1 x 2.5 mm²
Rigid 2 x 1.5 mm²
Power supply circuit connection capacity:
Rigid 1 x 2.5 mm²
Tightening torque:
Control Circuit 0.5 N·m
Main Circuit 28 N·m
Supply Circuit 0.5 N·m