EX-F61-PN

Subscribe to get prices

Model: EX-F61-PN

Order No:

SKU: 10000056578201

Size: 16.00 cm,5.00 cm,7.00 cm

Weight: 100.00g

In Stock

Brief Introduction

EX-F61-PN

Sensing object Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.<br/> Note : Highly viscous liquid may not be detected stably.<br/> Note : The agents mentioned above are examples. For details, please contact our office.<br/> Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.<br/> Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less<br/> Current consumption 15 mA or less<br/> Output NPN open-collector transistor<br/> - Maximum sink current: 50 mA<br/> - Applied voltage: 30 V DC or less (between output and 0 V)<br/> - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 17 mA sink current)<br/> Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF

Description

As of November 23, 2023
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number EX-F61-PN
Part Number EX-F61-PN
Sensing object Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc.
Note : Highly viscous liquid may not be detected stably.
Note : The agents mentioned above are examples. For details, please contact our office.
Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office.
Supply voltage 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 15 mA or less
Output PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (between output and +V)
- Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current)
Output:Output operation In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
Output:Short-circuit protection Incorporated
Response time 50 ms or less
FAULT indicator Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
NORMAL indicator Green LED (lights up when the sensor is mounted properly)
Protection IP67 (IEC)
Ambient temperature -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉
Note : Liquid being detected should also be kept within the rated ambient temperature range.
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 1,000 ℓx or less at the light-receiving face
Emitting element Infrared LED (non-modulated)
Material Enclosure: PFA
Cable extension Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
Weight Net weight: 60 g approx.
Accessory MS-EX-F6-1(PFA mounting bracket): 1 pc.