SIEMENS 6ES7336-1HE00-0AB0

6ES7336-1HE00-0AB0

Subscribe to get prices

Model: 6ES7336-1HE00-0AB0

Order No:

SKU: 10000004012701


Warning: Undefined array key "Condition" in /www/wwwroot/yinliu/templates_c/112dd6e875debbc5725df84087289a5b5cd4de3a_0.file_detail.tpl.php on line 73

Size: 0.00 cm,0.00 cm,0.00 cm

Weight: 2.00kg


Warning: Undefined array key "Product_Selection_Engineer" in /www/wwwroot/yinliu/templates_c/112dd6e875debbc5725df84087289a5b5cd4de3a_0.file_detail.tpl.php on line 79

In Stock

Brief Introduction

6ES7336-1HE00-0AB0

td{vertical-align: top} .Kapitelfarbe20_NO_DATA_thinline80 { background-color: #CCE8FF; border-top: solid #000000 1px; } .Kapitelfarbe_NO_DATA_NO_DATA { background-color: #008CFF; } .Schwarz25_NO_DATA_NO_DATA { background-color: #C0C0C0; } .sf_H2_0_0_0 { color: #FFFFFF; font-family: "arial", "geneva", "helvetica"; font-size: 10pt; font-weight: bold; padding-left: 5px; } .sf_mainTAK_0_0_0__0_0_0_0_0__NO_DATA_NO_DATA_thinline80 { font-family: "arial", "geneva", "helvetica"; font-size: 9pt; padding-left: 5px; border-top: solid #000000 1px; } .sf_standard_0_0_0 { font-family: "arial", "geneva", "helvetica"; font-size: 9pt; padding-left: 5px; } .sf_standard_0_0_0__0_0_0_0_0__Kapitelfarbe20_NO_DATA_NO_DATA { font-family: "arial", "geneva", "helvetica"; font-size: 9pt; padding-left: 5px; background-color: #CCE8FF; } .sf_standard_0_0_0__0_0_0_0_0__Kapitelfarbe20_NO_DATA_thinline80 { font-family: "arial", "geneva", "helvetica"; font-size: 9pt; padding-left: 5px; background-color: #CCE8FF; border-top: solid #000000 1px; } .sf_standard_1_0_0 { font-family: "arial", "geneva", "helvetica"; font-size: 9pt; padding-left: 5px; text-align: center; } .sf_subTAK_0_0_1__0_0_0_0_0__NO_DATA_NO_DATA_NO_DATA { font-family: "arial", "geneva", "helvetica"; font-size: 9pt; list-style-type: circle; }     Artikelnummer 6ES7336-1HE00-0AB0 SIMATIC S7, ANALOG INPUT SM336, 6 AI; 14 BIT; 40 PIN, FAILSAFE ANALOG INPUTS FOR SIMATIC S7F SYSTEMS WITH DIAGNOST. INTERRUPT Supply voltage Load voltage L+ ● Rated value (DC) 24 V ● Reverse polarity protection Yes Input current from backplane bus 5 V DC, max. 90 mA from supply voltage L+, max. 160 mA; Typical Power losses Power loss, typ. 4.25 W Analog inputs Number of analog inputs 6 Number of analog inputs for voltage measurement 4 permissible input voltage for voltage input (destruction limit), max. 30 V permissible input current for current input (destruction limit), max. 40 mA Input ranges ● Voltage Yes ● Current Yes Input ranges (rated values), voltages ● 0 to +10 V Yes ● Input resistance (0 to 10 V) 59 kΩ Input ranges (rated values), currents ● 0 to 20 mA Yes ● Input resistance (0 to 20 mA) 107 Ω ● 4 to 20 mA Yes ● Input resistance (4 to 20 mA) 107 Ω Cable length ● Cable length, shielded, max. 200 m Analog value creation Integration and conversion time/resolution per channel ● Resolution with overrange (bit including sign), max. 14 bit ● Integration time, ms 20 ms (at 50 Hz); 16.66 ms (at 60 Hz) ● Interference voltage suppression for interference frequency f1 in Hz 38 dB Encoder Connection of signal encoders ● for current measurement as 2-wire transducer Yes ● for current measurement as 4-wire transducer Yes Errors/accuracies Operational limit in overall temperature range ● Voltage, relative to input area, (+/-) 0.48 % ● Current, relative to input area, (+/-) 0.48 % Basic error limit (operational limit at 25 °C) ● Voltage, relative to input area, (+/-) 0.4 % ● Current, relative to input area, (+/-) 0.4 % Interrupts/diagnostics/status information Alarms ● Diagnostic alarm Yes; Parameterizable Diagnostic messages ● Diagnostic functions Yes ● Diagnostic information readable Yes Diagnostics indication LED ● Fail-safe operation Yes ● Group error SF (red) Yes ● Monitoring 24 V voltage supply ON (green) Yes; Encoder supply Galvanic isolation Galvanic isolation analog inputs ● between the channels No ● between the channels and the backplane bus Yes ● between the channels and the power supply of the electronics Yes; only if sensors are externally supplied Isolation Isolation checked with 500V DC/350V AC Standards, approvals, certificates Highest safety class achievable in safety mode ● acc. to DIN V 19250 AK 6 ● acc. to EN 954 Cat. 4 ● acc. to IEC 61508 SIL 3 Connection method required front connector 40-pin Dimensions Width 80 mm Height 125 mm Depth 120 mm Weights Weight, approx. 480 g last modified: 08.09.2014

Description

  
 
Artikelnummer 6ES7336-1HE00-0AB0
SIMATIC S7, ANALOG INPUT SM336, 6 AI; 14 BIT; 40 PIN, FAILSAFE ANALOG INPUTS FOR SIMATIC S7F SYSTEMS WITH DIAGNOST. INTERRUPT
Supply voltage
Load voltage L+
● Rated value (DC) 24 V
● Reverse polarity protection Yes
Input current
from backplane bus 5 V DC, max. 90 mA
from supply voltage L+, max. 160 mA; Typical
Power losses
Power loss, typ. 4.25 W
Analog inputs
Number of analog inputs 6
Number of analog inputs for voltage measurement 4
permissible input voltage for voltage input (destruction limit), max. 30 V
permissible input current for current input (destruction limit), max. 40 mA
Input ranges
● Voltage Yes
● Current Yes
Input ranges (rated values), voltages
● 0 to +10 V Yes
● Input resistance (0 to 10 V) 59 kΩ
Input ranges (rated values), currents
● 0 to 20 mA Yes
● Input resistance (0 to 20 mA) 107 Ω
● 4 to 20 mA Yes
● Input resistance (4 to 20 mA) 107 Ω
Cable length
● Cable length, shielded, max. 200 m
Analog value creation
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max. 14 bit
● Integration time, ms 20 ms (at 50 Hz); 16.66 ms (at 60 Hz)
● Interference voltage suppression for interference frequency f1 in Hz 38 dB
Encoder
Connection of signal encoders
● for current measurement as 2-wire transducer Yes
● for current measurement as 4-wire transducer Yes
Errors/accuracies
Operational limit in overall temperature range
● Voltage, relative to input area, (+/-) 0.48 %
● Current, relative to input area, (+/-) 0.48 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input area, (+/-) 0.4 %
● Current, relative to input area, (+/-) 0.4 %
Interrupts/diagnostics/status information
Alarms
● Diagnostic alarm Yes; Parameterizable
Diagnostic messages
● Diagnostic functions Yes
● Diagnostic information readable Yes
Diagnostics indication LED
● Fail-safe operation Yes
● Group error SF (red) Yes
● Monitoring 24 V voltage supply ON (green) Yes; Encoder supply
Galvanic isolation
Galvanic isolation analog inputs
● between the channels No
● between the channels and the backplane bus Yes
● between the channels and the power supply of the electronics Yes; only if sensors are externally supplied
Isolation
Isolation checked with 500V DC/350V AC
Standards, approvals, certificates
Highest safety class achievable in safety mode
● acc. to DIN V 19250 AK 6
● acc. to EN 954 Cat. 4
● acc. to IEC 61508 SIL 3
Connection method
required front connector 40-pin
Dimensions
Width 80 mm
Height 125 mm
Depth 120 mm
Weights
Weight, approx. 480 g