USD
- USD
- CNY
- HKD
- EUR
English
- العربية
- čeština
- dansk
- Deutsch
- Ελληνικά
- English
- Español
- Français
- ic
- Italiano
- Netherlands
- norsk Språk
- język polski
- pt
- Português
- 中文
Surge protector Price List
Model | Description | Leading | Price |
---|---|---|---|
Maximum continuous working voltage: AC 385VMaximum discharge current: 20KA Rated discharge current: 10KA Number of poles: 1P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 40KA Rated discharge current: 20KA Number of poles: 1P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 60KA Rated discharge current: 30KA Number of poles: 1P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 80KA Rated discharge current: 40KA Number of poles: 1P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 100KA Rated discharge current: 50KA Number of poles: 1P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 12.5KA Rated discharge current: 12.5KA Number of poles: 1P Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 15KA Rated discharge current: 15KA Number of poles: 1P Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 25KA Rated discharge current: 25KA Number of poles: 1P Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 50KA Rated discharge current: 50KA Number of poles: 1P Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 1800KA Rated discharge current: 100KA Number of poles: 1P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 20KA Rated discharge current: 10KA Number of poles: 1P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 40KA Rated discharge current: 20KA Number of poles: 1P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 60KA Rated discharge current: 30KA Number of poles: 1P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 80KA Rated discharge current: 40KA Number of poles: 1P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 100KA Rated discharge current: 50KA Number of poles: 1P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 12.5KA Rated discharge current: 12.5KA Number of poles: 1P+N Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 15KA Rated discharge current: 15KA Number of poles: 1P+N Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 25KA Rated discharge current: 25KA Number of poles: 1P+N Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 50KA Rated discharge current: 50KA Number of poles: 1P+N Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 180KA Rated discharge current: 100KA Number of poles: 1P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 20KA Rated discharge current: 10KA Number of poles: 3P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 40KA Rated discharge current: 20KA Number of poles: 3P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 60KA Rated discharge current: 30KA Number of poles: 3P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 80KA Rated discharge current: 40KA Number of poles: 3P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 100KA Rated discharge current: 50KA Number of poles: 3P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 12.5KA Rated discharge current: 12.5KA Number of poles: 3P Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 15KA Rated discharge current: 15KA Number of poles: 3P Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 25KA Rated discharge current: 25KA Number of poles: 3P Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 50KA Rated discharge current: 50KA Number of poles: 3P Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 180KA Rated discharge current: 100KA Number of poles: 3P Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 20KA Rated discharge current: 10KA Number of poles: 3P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 40KA Rated discharge current: 20KA Number of poles: 3P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 60KA Rated discharge current: 30KA Number of poles: 3P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 80KA Rated discharge current: 40KA Number of poles: 3P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 100KA Rated discharge current: 50KA Number of poles: 3P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 12.5KA Rated discharge current: 12.5KA Number of poles: 3P+N Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 15KA Rated discharge current: 15KA Number of poles: 3P+N Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 25KA Rated discharge current: 25KA Number of poles: 3P+N Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 50KA Rated discharge current: 50KA Number of poles: 3P+N Protection level: Type I protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
|
Maximum continuous working voltage: AC 385VMaximum discharge current: 180KA Rated discharge current: 100KA Number of poles: 3P+N Protection level: Type II protection Installation dimensions: 35mm DIN rail mount
|
In Stock
|
Subscribe
|
Unsubscribe
Subscribe
Subscription successful
Price list will be sent to you by email within 24hrs.