VAT-UP200-X-P-A

Subscribe to get prices

Model: VAT-UP200-X-P-A

Order No:

SKU: 10000125480801

Size: 0.00 mm,0.00 mm,0.00 mm

Weight: 0.00KG

In Stock

Brief Introduction

VAT-UP200-X-P-A

Description

Ø  Universal AC input (90~264Vac)

Ø  With Active PFC, PF>0.95

Ø  Surge 300Vac for 60S

Ø  High Efficiency, long life and High reliability

Ø  Output protections: OLP/OVP/SCP/OPP

Ø  1+1 parallel function, current sharing

Ø  Wide operating ambient temperature (-40℃~65℃)

Ø  Operating altitude up to5000m

Ø  All using 105℃ long life electrolytic capacitors.

Ø  100% full load burn-in test

Ø  Fanless, quiet working

Ø  PCB with conformal coating

Ø  Low profile, 30mm

Ø  3 years warranty

MODEL

VAT-UP200-4.2-P-A

VAT-UP200-5-P-A

OUTPUT

DC Output

4.2V

5V

Rated Current

40A

40A

CurrentRange    Note 1

0~40A

0~40A

Peak load

50A(50mS, 220Vac input)

Ripple and Noise 

Note 2

0~65℃

≤150MV

≤200MV

Voltage Accuracy@-40~65C

4.15~4.4V

±3%

Line Regulation/

±0.5%

Load Regulation

±2%

Set-up Time @25℃

≤2S (220Vac input,40A)

Hold up Time

≥5mS (220Vac input,32A)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

Parallel (current sharing)

Current-unbalance< 10% (single PS drive40Aload, the voltage of current share bus is 2.9~4V)

INPUT

VoltageRange  Note 3

90Vac~264Vac

FrequencyRange

47Hz~63Hz

Efficiency ( Typical)

86% (220Vac input,40A)

88% (220Vac input,40A)

AC Current (max.)

<3.5A

Inrush Current (Typical)

<60A@220Vac     Cold start

Power Factor @25℃

>0.95 (input 220Vac,40A)

Stand by power consumption

<4W (input 220Vac)

Leakage Current

Input—output:<0.25mA    Input—PG:<3.5mA  (input 264Vac, 63Hz)

PROTECTION

Over Load

44~65A, hiccup mode, auto recovery

44~65A, hiccup mode, auto recovery

Over Power

184.8~252W, hiccup mode, auto recovery

220~325W, hiccup mode, auto recovery

Over Voltage

4.5~6.5V, hiccup mode, auto recovery

5.2~6.5V, constant voltage

Over Temperature

105℃+5℃(detect on temperature controller);shut down, auto recovery after the temperature goes down to65℃

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-40℃~65℃; 20%~90%RH No condensing(refer to the derating curve)

Storage Temp. & Hum.

-40℃~85℃; 10%~95%RH No condensing

SAFETY &EMC  

(Note 4)

Safety Standards

UL60950-1 2ndEd; IEC 60950-1:2005(2ndEd) ;EN60950-1:2006


Withstand Voltage

Primary-Secondary: 3.0KVac/10mA .Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.

Isolation Resistance

10Mohms

EMI Conduction&Radiation

Compliance to EN55022  CLASS B

EMSImmunity

Compliance toEN61000-4-2,3,4,5,6,8,11;

OTHERS

MTBF (MIL-HDBK-217F)

>200000h (25℃, Full load)

Dimension (L*W*H)

133*55*30mm

Packing

49PCS/CTN, 15KGS, 0.04CBM

Power Good Signal

Working properly, port voltage: 3.0~3.5V(output current 0~1mA)

Working abnormally, port voltage: 0~0.7V(pull-up resistor > 10K)

Cooling method

Cooling by free air convection

NOTE

1.    All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.    Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” onhttps://www.powerld.com.


We provide high-quality LED power supplies for indoor and outdoor, and a variety of specifications and models of LED power supplies are optional, suitable for specific lighting applications in multiple fields.

Unsubscribe

Discount Code

Subscribe
: 0.023045063018799