Ø Universal AC input (90~264Vac)
Ø With Active PFC, PF>0.95
Ø High Efficiency, long life and High reliability
Ø Surge 300Vac for 60s
Ø Output protections: OLP/OVP/SCP/OPP
Ø Wide operating ambient temperature (-40℃~65℃)
Ø Operating altitude up to5000m
Ø All using 105℃ long life electrolytic capacitors.
Ø 100% full load burn-in test
Ø Fanless, quiet working
Ø PCB both side with conformal coating
Ø 2 years warranty
MODEL |
VAT-UP300L-5-E |
VAT-UP300L-4.2-E |
|||
OUTPUT |
DC Output |
5V |
4.2V |
||
Rated Current |
60A |
60A |
|||
Current Range Note 1 |
0~60A |
3~60A |
|||
Peak load |
70A (50mS, 220Vac input) |
||||
Ripple and Noise Note 2 |
0~65℃ |
≤200mV (100M bandwidth) ; ≤150MV (20M bandwidth) |
|||
-40℃ |
≤400mV (100M bandwidth) |
||||
Voltage Accuracy |
±3% |
||||
Line Regulation/ |
±0.5%
|
||||
Load Regulation |
±2%
|
||||
Set-up Time |
≤3S (220Vac input,60A) |
||||
Hold up Time |
≥4mS (220Vac input,60A) |
||||
Temperature Coefficient |
±0.03%/℃ |
||||
Overshoot and Undershoot |
<5.0% |
||||
INPUT |
Voltage Range Note 3 |
90Vac~264Vac |
|||
Frequency Range |
47Hz~63Hz |
||||
Efficiency ( Typical) |
110Vac input |
≥87% |
≥86% |
||
230Vac input |
≥90% |
≥88% |
|||
AC Current (max.) |
<5A |
||||
Inrush Current (Typical) |
<30A@220Vac Cold start |
||||
Power Factor @25℃ |
>0.95 (input 220Vac,60A) |
||||
Leakage Current |
Input—output:<0.25mA Input—PG:<3.5mA (input 264Vac, 63Hz) |
||||
PROTECTION |
Over Load |
63~80A, hiccup mode, auto recovery |
Unsubscribe